On Wednesday 25th September 2024 we released version 9.9.5.41 as (what’s currently, as I type this note) the ‘Latest and Greatest’ version available for download and install here.
This version contains a number of enhancements to the ‘Constraint Dashboard’ widget* that we’d like to describe in this focused* Release Note – at least in part because we’ll be contacting some of our clients directly about these particular enhancements, with some questions as well.
* many other widgets have also been enhanced, but this Release Note only highlights what we have done on only this particular widget.
The enhancements we’ve been focused on in ez2view have included, but not been restricted to, consideration of these ‘Known Limitations with the ‘Transition Release of ez2view on 27th May 2024’.
(A) Background
It was back in this Release Note for v9.5 on 10th October 2022 that we illustrated what had been delivered (at that time) with respect to the ‘Constraint Dashboard’ widget.
As noted in ‘What is IESS, and why is it relevant to ez2view’ on 28th April 2024, the bi-directional nature of the way the EMMS stores data (and NEMDE considers BDUs) necessitated an upgrade to a number of widgets … including the ‘Constraint Dashboard’ widget.
Much more recently, on 19th September 2024 we utilised a slightly earlier-than-current version of the software (v9.9.5.12, released Tue 17th Sept 2024) to illustrate several constraint equations (and in particular the ‘N^^V_CTMN_1’ Constraint Equation) in the WattClarity article ‘Delivering oscillations, whilst seeking to minimise oscillations? A Case Study (Part 1?) of Darlington Point Solar Farm on Thursday 29th August 2024’.
(B) Using that example to illustrate a ‘Next Day Public’ view
The example used in that article just happened to be a good illustration of some of the changes made in – so we’ll use that specific example to . Specifically:
1) The ‘N^^V_CTMN_1’ Constraint Equation
2) Time-travelled back to 08:00 on Thursday 29th August 2024.
Here’s an image, with more details discussed in the table below:
Click on the image to open a larger view in a separate tab.
The image has been annotated with several numbers, corresponding to the table line items below with
| Item | Description |
|---|---|
|
1 |
For a start, note that the table on the right has been re-arranged to better suit the widening of the display (compared to v9.5). |
|
2 |
We see that two column-sets has been widened to enable the new bi-directionality necessitated by the IESS changes: (a) These columns are as follows: i. The ‘Target/Available’ columns; and ii. The ‘Next MW (L), Last MW, and Next MW (G)’ columns. (b) For both column sets: i. Injections into the grid (i.e. ‘generation’) are to the right, as positive quantities ii. Withdrawals from the grid (i.e. consumption) are to the left, as negative quantities.
|
|
3 |
Furthermore, this bi-directionality has been imposed upon units that are, native in the EMMS, still represented the ‘old’ way (i.e. with consumption being a positive quantity). In this example there are two units: (a) SNOWYP (the pumping for Tumut); and (b) BHBL1 i. This is the old ‘load-side’ DUID that still exists at this point for the Broken Hill BESS ii. At this dispatch interval, the facility: 1. has already transitioned to be a BDU at this point, 2. but the old pair of DUIDs (i.e. L1 and G1) have yet to be retired … hence we need to list them in the Dashboard. |
|
4 |
It’s important to note here that, because we have changed the sign in the Dashboard of consumption at these two (non-transitioned) units, we have also needed to change the sign of the LHS factor … so the ‘Contribution’ calculation still works, mathematically. That’s what the tool-tip denotes. |
|
5 |
We’ve added several extra columns at the right-hand end of the table, to help users more quickly understand the context to the data. These are: Addition #1) Region (i.e. or interconnector) Addition #2) Dispatch Type (e.g. now catering for the new Dispatch Type of BDU) Addition #3) Market (i.e. to differentiate FCAS elements that sometimes are included in the mix of LHS terms). |
|
6 |
We’ve slightly modified the colouring of the WHITE/PINK/GREY colour scheme in the ‘Target/Available’ column: (a) With the colour around unity being faded, to help the user clearly see which direction(s) are capable; and (b) Because of the bi-directional nature of some units, the scaling (to the left, and the right) of this column has been enhanced. |
|
7 |
In the same way that pink colour in ‘Target/Available’ column, we have now added the same pink colouring in the ‘Last MW’ column to make it easy to see when a unit had spare capacity at the same bid price (at the RRN) that already had received a non-zero Target. |
|
8 |
At the request of specific clients, we have added in interconnector icon into the left-most column, to differentiate it from ‘Other’ as a Fuel Type . |
|
9 |
Also at the request of specific clients, in the Target/Available column we have changed the representation of the interconnectors: (a) which can (obviously) flow in both positive and negative directions (b) … but where the bar has been removed to avoid confusion with injections and withdrawals. |
|
10 |
Not shown in the example above, but worth noting that (since we encountered the situation in the Victorian ‘Significant Power System Event’ on 13th February 2024) we have corrected some logic to ensure that: (a) where CPD Price is unable to be calculated from the set of data in the EMMS, dashes are shown instead; (b) this occurs in most situations of over-constrained dispatch (OCD) where the relevant data is overwritten by AEMO re-run processes. This approach was also taken in the ‘Unit Dashboard’ widget. |
There have been other minor tweaks as well …
(C) What the widget shows in Real Time.
We thought it was also worth including this second image to highlight the approach taken with this widget when it is in ‘Real Time’ mode (i.e. assuming it does not have access to Private Data for particular units).
The constraint equation above was an outage-related constraint, and not invoked when we wrote this note so in this case we’ve chosen the ‘V^^N_DPWG_1’ constraint equation because it was invoked (and bound) at the time of the snapshot … and because this one helps us illustrate a couple points:
Click on the image to open a larger view in a separate tab.
This second image has been annotated with several numbers, corresponding to the table line items below:
| Item | Description |
|---|---|
|
1 |
For line entries in the table that have access to the relevant data in realtime, the behaviour is the same as is noted above. For instance, we see this in the example of the two interconnectors (V-S-MNSP1 and VIC1-NSW1), for which we have published Targets in real time. |
|
2 |
In the case of all the other DUIDs, however, we don’t have Targets and so assume that the InitialMW for the DUIDs is the ‘best’ approximation of Target possible in Real Time. Note that the font changes to italicized to denote the difference. |
We have more planned for this widget
(D) For more information.
For further information about the Constraint Dashboard widget:
1) See the Widget Guide for ‘Constraint Dashboard’ in v9.9.5.*; and also
2) On WattClarity we’ve tagged some examples of use here.